Room acoustics

Room acoustics describes how sound behaves in an enclosed space.

The way that sound behaves in a room can be broken up into roughly four different frequency zones:

Natural modes

See also: Normal mode

The sound wave has reflections at the walls, floor and ceiling of the room. The incident wave then has interference with the reflected one. This action creates standing waves that generate nodes and high pressure zones.[3]

In 1981, in order to solve this problem, Oscar Bonello, professor at the University of Buenos Aires, formulated a modal density concept solution which used concepts from psychoacoustics.[4] Called "Bonello Criteria", the method analyzes the first 48 room modes and plots the number of modes in each one-third of an octave. The curve increases monotonically (each one-third of an octave must have more modes than the preceding one).[5] Other systems to determine correct room ratios have more recently been developed [6]

Reverberation of the room

After determining the best dimensions of the room, using the modal density criteria, the next step is to find the correct reverberation time. The most appropriate reverberation time depends on the use of the room. Times about 1.5 to 2 seconds are needed for opera theaters and concert halls. For broadcasting and recording studios and conference rooms, values under one second are frequently used. The recommended reverberation time is always a function of the volume of the room. Several authors give their recommendations [7] A good approximation for Broadcasting Studios and Conference Rooms is: TR[1 kHz] = [0,4 log (V+62)] – 0,38 TR in seconds and V=volume of the room in m3 [8] The ideal RT60 must have the same value at all frequencies from 30 to 12,000 Hz. Or, at least, it is acceptable to have a linear rising from 100% at 500 Hz to 150% down to 62 Hz

To get the desired RT60, several acoustics materials can be used as described in several books.[9][10] A valuable simplification of the task was proposed by Oscar Bonello in 1979 [11] It consists of using standard acoustic panels of 1 m2 hung from the walls of the room (only if the panels are parallel). These panels use a combination of three Helmholtz resonators and a wooden resonant panel. This system gives a large acoustic absorption at low frequencies (under 500 Hz) and reduces at high frequencies to compensate for the typical absorption by people, lateral surfaces, ceilings, etc.

See also

Compare

References

  1. "Sound System Engineering" 4th edition, Don Davis, Eugene Patronis, Pat Brown, June 2013, page 215
  2. "Handbook of Noise and Vibration Control", Malcolm J. Crocker, 2007, page 54
  3. “Acoustics”, Leo Beranek, chapter 10, McGraw Hill Books, 1954
  4. "A NEW CRITERION FOR THE DISTRIBUTION OF NORMAL ROOM MODES" - Journal of the Audio Engineering Society (USA) Vol. 29, Nro. 9 - September/1981. Oscar Bonello
  5. Handbook for Sound Engineers Glen Ballou, Howards Sams Editors, page 56.
  6. Cox, TJ, D'Antonio, P and Avis, MR 2004, "Room sizing and optimization at low frequencies." , Journal of the Audio Engineering Society, 52 (6) , pp. 640-651.
  7. “Acoustics”, Leo Beranek, chapter 13, McGraw Hill Books, 1954
  8. “Clases de Acústica”, Oscar Bonello, Edited CEI, Facultad de Ingeniería UBA
  9. Rettinger, Michael (1977). Acoustic Design and Noise Control. New York: Chemical Publishing.
  10. Knudsen, Vern Oliver; Cyril M. Harris. Acoustical designing in Architecture. New York: John Wiley and Sons.
  11. “A new computer aided method for the complete acoustical design of broadcasting and recording studios”, Oscar Bonello, 1979 IEEE International Conference on Acoustics, Speech and Signal Processing, Washington


This article is issued from Wikipedia - version of the 9/27/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.